Tao Shao 1Xianning Xu 1Lan Wang 2Yu Shen 1[ ... ]Lin Li 1,2,4,***
Author Affiliations
Abstract
1 Frontiers Science Center for Flexible Electronics, Xi’an Institute of Flexible Electronics (IFE) and Xi’an Institute of Biomedical Materials & Engineering, Northwestern Polytechnical University, Xi’an 710072, P. R. China
2 Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211816, P. R. China
3 Department of Outpatient, PLA Rocket Force Characteristic Medical Center, Beijing 100088, P. R. China
4 The Institute of Flexible Electronics (IFE, Future Technologies), Xiamen University, Xiamen 361005, Fujian, P. R. China
Peroxynitrite (ONOO) contributes to oxidative stress and neurodegeneration in Parkinson’s disease (PD). Developing a peroxynitrite probe would enable in situ visualization of the overwhelming ONOO flux and understanding of the ONOO stress-induced neuropathology of PD. Herein, a novel α-ketoamide-based fluorogenic probe (DFlu) was designed for ONOO monitoring in multiple PD models. The results demonstrated thatDFlu exhibits a fluorescence turn-on response to ONOO with high specificity and sensitivity. The efficacy ofDFlu for intracellular ONOO imaging was demonstrated systematically. The results showed thatDFlu can successfully visualize endogenous and exogenous ONOO in cells derived from chemical and biochemical routes. More importantly, the two-photon excitation ability ofDFlu has been well demonstrated by monitoring exogenous/endogenous ONOO production and scavenging in live zebrafish PD models. This work provides a reliable and promising α-ketoamide-based optical tool for identifying variations of ONOO in PD models.
α-Ketoamide two-photon fluorogenic probe bioimaging peroxynitrite Parkinson’s disease 
Journal of Innovative Optical Health Sciences
2023, 16(4): 2250039
作者单位
摘要
1 省部共建电工装备可靠性与智能化国家重点实验室, 河北工业大学, 天津 300130
3 国民核生化灾害防护国家重点实验室, 北京 102205
4 等离子体科学和能源转化北京市国际科技合作基地, 中国科学院电工研究所, 北京 100190
化学气体毒剂杀伤快、 易扩散、 难处置, 一旦使用或泄露将对****和社会稳定造成巨大威胁, 因此有必要发展一种可以现场实时检测化学毒害气体的方法。 目前, 传统气体检测方法主要包括红外吸收光谱、 气相色谱/质谱、 离子迁移谱和各种气体传感器等, 但其便携性、 灵敏度、 广谱性难以兼得, 无法完全满足现场检测需求。 基于发射光谱(OES)响应快、 灵敏度高、 广谱性好、 可重复性强的独特优势, 提出了一种大气压低温等离子体发射光谱检测技术。 分别以纳秒高压脉冲、 直流自脉冲和微波作为等离子体激励源, 使用毒性较小的甲基膦酸二甲酯(DMMP)作为沙林模拟剂进行发射光谱检测; 以乙醇作为环境有机干扰物, 对乙醇与DMMP光谱进行了主成分分析; 并探究了放电脉冲频率与特征光谱强度的关系。 结果表明, 三种激励源产生的等离子体都可辨别出DMMP特征光谱: P原子特征谱线波长为213.82和215.09 nm, PO基团谱带波长为253.67和255.6 nm。 光谱识别度方面, 使用微波激励源时DMMP特征光谱最为明显, 而使用纳秒脉冲与直流自脉冲激励源时光谱连续本底强烈。 方法适用性方面, 微波等离子体无电极污染、 但需要氩气维持, 可作为建立毒害气体发射光谱数据库的手段; 而纳秒脉冲与直流自脉冲激励源可在常压空气环境中直接检测。 三种激励形式下等离子体区域都存在气体加热效应, 微波等离子体气体温度最高(约1 300 K), 而纳秒脉冲和直流自脉冲放电气体温度相近(分别约为980和880 K)。 研究发现, 提升脉冲重复频率可以显著增加DMMP特征光谱强度, 其与脉冲频率在1~40 kHz内呈线性关系(相关系数大于0.98)。 所提出的大气压等离子体发射光谱检测方法具有响应快、 操作简单等优点, 可扩展性强、 具有小型化潜力, 为毒害气体快速检测装备研发提供了技术参考。
大气压等离子体 光谱诊断 气体检测 Atmospheric pressure plasma Spectral diagnosis Gas detection 
光谱学与光谱分析
2022, 42(6): 1728
作者单位
摘要
1 中国科学院 电工研究所 等离子体科学和能源转化北京市国际科技合作基地,北京 100190
2 中国科学院大学,北京 100049
研制了一种双极性交替的纳秒高压脉冲电源,进行了双极性纳秒脉冲放电产生等离子体研究。该电源先通过固态开关IGBT将直流电压截断成电压脉冲,通过可饱和脉冲变压器拓扑,实现升压并缩短脉冲上升沿。该电源可在一个周期内输出极性相反的2个脉冲,且时序可以灵活控制。通过优化调整器件参数,研制了两种不同输出性能参数的双极性纳秒脉冲电源:①峰值电压10 kV、爆发模式脉冲重复频率500 kHz(正负脉冲间隔2 μs)、连续重复频率1 kHz;②峰值电压25 kV、爆发重频200 kHz、连续重频600 Hz。测试电源的运行性能,发现电源存在温度升高的情况,但长时间(>0.5 h)运行温度趋于稳定。10 kV电源连续运行在1 kHz时最高温度点50.5 ℃;25 kV电源连续运行在600 Hz时最高温度点60 ℃。利用该电源驱动线板电极阵列和表面介质阻挡放电结构,证实了该电源可以用于常压空气条件下产生大面积等离子体。
双极性脉冲电源 磁压缩 固态开关 纳秒脉冲放电 大气压等离子体 bi-polar pulse generator magnetic compression solid-state switch nanosecond pulse discharge atmospheric-pressure plasma 
强激光与粒子束
2021, 33(6): 065005
Author Affiliations
Abstract
1 Laboratory of Optical Radiation of the Institute of High Current Electronics, Tomsk 634055, Russia
2 National Research Tomsk State University, Tomsk 634050, Russia
3 National Research Tomsk Polytechnic University, Tomsk 634050, Russia
4 Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing 100190, China
Supershort avalanche electron beam (SAEB) plays an important role in nanosecond-pulse discharges. this paper aims at reviewing experiments results on characteritics of SAEB and its spectra in different gases in nanosecond-pulse discharges. All the joint experiments were carried in the Institute of High Current Electronics of the Russian Academy of Sciences and the Institute of Electrical Engineering of the Chinese Academy of Sciences. In these experiments, the generation of a SAEB in SF6 in an inhomogeneous electric field was studied on three generators with pulse rise times of 0.3, 0.5 and ~2 ns. Firstly, the comparison of SAEB parameters in SF6 with those obtained in other gases (air, nitrogen, argon, and krypton) is introduced. Secondly, the SAEB spectra in SF6 and air at pressures of 10 kPa (75 torr), and 0.1 MPa (750 torr) are reviewed and discussed. Finally, 1.5-D theoretical simulation of the supershort pulse of the fast electron beam in a coaxial diode filled with SF6 at atmospheric pressure is described. the simulation was carried out in the framework of hybrid model for discharge and runaway electron kinetics. the above research progress can provide better understanding of the investigation into the mechanism of nanosecond-pulse discharges.
Runaway electrons Runaway electrons Supershort avalanche electron beam (SAEB) Supershort avalanche electron beam (SAEB) SF6 SF6 Gas diode Gas diode High pressure High pressure Simulation Simulation Hybrid model Hybrid model 
Matter and Radiation at Extremes
2017, 2(3): 105
沈苑 1,2王瑞雪 2,3章程 2,3方志 1邵涛 2,3
作者单位
摘要
1 南京工业大学 自动化与电气工程学院, 南京 210009
2 中国科学院 电工研究所, 北京 100190
3 中国科学院 电力电子与电气驱动重点实验室, 北京 100190
研究了不同电极结构以及放电参数对微秒脉冲激励的氦等离子体射流放电特性的影响。实验中采用不同管内径、不同电极形状、不同重复频率等参数,通过采集放电阶段的电流电压图、发光图像以及发射光谱等,对等离子体射流的电学特性和光学特性进行诊断。实验结果表明,随着管内直径的增大,氦等离子体射流的长度减小; 管内径为8 mm时,等离子体射流的击穿电压与放电电流最小,同时,其发射光谱中第二正带系N2,N+2和O等高能活性粒子的强度最高; 管内径为5 mm的等离子体射流的放电电流、功率及消耗的能量最大; 在相同实验条件下,针尖电极结构中的放电电流、消耗的功率还有发射光谱强度都较大; 随着重复频率的增加,氦等离子体射流的长度会增加,但击穿电压减小。
等离子体射流 电极结构 重复频率 放电参量 plasma jet electrode structure pulse repetition frequency discharge parameter 
强激光与粒子束
2016, 28(5): 055001
王磊 1,2章程 1,3罗振兵 4王林 4[ ... ]邵涛 1,3
作者单位
摘要
1 中国科学院 电工研究所, 北京 100190
2 中国科学院大学, 北京 100039
3 中国科学院 电力电子与电气驱动重点实验室, 北京 100190
4 国防科学技术大学 航天科学与工程学院, 长沙 410073
为了产生高能等离子体合成射流,设计了一台面向等离子体合成射流应用的微秒脉冲源,输出电压为10 kV,重复频率为100 Hz,可承受高达250 A的放电电流。详细介绍了微秒脉冲源的工作原理,比较了不同放电电容对脉冲变压器原边电流及输出电压的影响。进一步将所设计的微秒脉冲源成功应用于等离子体合成射流实验中,研究了不同间距对等离子体合成射流的影响,比较了有无放电电容条件下的能量消耗率。实验结果表明: 不同放电电容在相同激励器间距的条件下,击穿电压基本相同; 击穿电压随激励器间距增大而增大。有放电电容能产生较大的放电电流,且电流值随电容值的增大而增大。有放电电容条件下的能量消耗率比无放电电容要高,易于产生高能的等离子体合成射流。
等离子体合成射流 激励器 微秒脉冲源 放电电容 能量消耗率 plasma synthetic jet actuator microsecond pulse power discharge capacitor rate of energy dissipated 
强激光与粒子束
2016, 28(4): 045013
顾建伟 1,2,*章程 1,3王瑞雪 1,3侯兴民 1,2[ ... ]邵涛 1,3
作者单位
摘要
1 中国科学院 电工研究所, 北京 100190
2 中国科学院大学, 北京 100190
3 中国科学院 电力电子与电气驱动重点实验室, 北京 100190
利用上升沿约0.5 μs、半高宽约6 μs、幅值可达40 kV的微秒脉冲电源和上升沿约150 ns、半高宽约300 ns、幅值可达50 kV的纳秒脉冲电源激励大气压弥散放电, 并分别采用刀型和锯齿电极放电。通过电压电流测量和发光图像拍摄, 改变施加电压种类、脉冲重复频率、高压电极结构和气隙距离等参数, 研究了不同条件下弥散放电特性。实验结果表明: 纳秒脉冲电源和微秒脉冲电源均能在大气压空气中激励大面积的弥散放电, 弥散放电面积最大达90 cm2; 放电的均匀性受脉冲参数与电极形状影响显著, 其中刀型电极条件下纳秒脉冲激励的弥散放电均匀性最佳; 相同条件下纳秒脉冲弥散放电的瞬时功率大于微秒脉冲弥散放电, 最高可达275 kW, 而纳秒脉冲弥散放电的能量小于微秒脉冲弥散放电; 保持其他条件不变, 弥散放电传导电流幅值随着气隙距离的增加而降低, 放电强度随着脉冲重复频率的增加而增强, 弥散放电的工作电压范围随着脉冲重复频率的增加显著降低。因此在低频、刀型电极结构中易于获得均匀与较大工作电压范围的大气压弥散放电。
弥散放电 纳秒脉冲 微秒脉冲 刀型电极 锯齿电极 气隙距离 重复频率 diffuse discharge nanosecond pulse microsecond pulse knife blade electrode saw blade electrode gap distance pulse repetition frequency 
强激光与粒子束
2016, 28(1): 015023
王磊 1,2,*章程 1,3高迎慧 1,3刘坤 1,3[ ... ]邵涛 1,3
作者单位
摘要
1 中国科学院 电工研究所, 北京 100190
2 中国科学院大学, 北京 100039
3 中国科学院 电力电子与电气驱动重点实验室, 北京 100190
4 国防科学技术大学 航天科学与工程学院, 长沙 410073
为满足脉冲功率源对高电压、大电流开关的需求,利用传统晶闸管均压技术,将多个晶闸管串联,研制出额定电压10 kV,额定电流500 A的晶闸管串联开关。根据晶闸管的触发原理,设计出同步触发多个晶闸管的触发系统。该触发系统采用绝缘栅双极型晶体管开关对直流电压阻断产生脉宽可调的低压脉冲,经多个隔离脉冲变压器升压,产生多路同步触发信号。对晶闸管触发系统及晶闸管串联开关进行了测试,测试结果表明:晶闸管触发系统可输出20 V,1 A的多路同步触发信号,触发信号的脉宽30~60 μs可调,重复频率100 Hz;晶闸管串联开关每路静态均压和动态均压波动小,在高电压条件下能稳定工作。
脉冲功率 晶闸管串联 同步触发 静态均压 动态均压 pulsed power series-connected thyristor synchronous triggering static voltage active voltage 
强激光与粒子束
2015, 27(11): 115001
黄伟民 1,2,*邵涛 1,3张东东 1,3马浩 1,2[ ... ]周杨 1,2
作者单位
摘要
1 中国科学院 电工研究所, 北京 100190
2 中国科学院大学, 北京 100039
3 中国科学院 电力电子与电气驱动重点实验室, 北京 100190
4 电力设备电气绝缘国家重点实验室 (西安交通大学), 西安 710049
针对实验产生等离子体的需求,研制了一种高压微秒脉冲电源,输出电压最大值为30 kV,上升沿最小为300 ns、脉宽0.5 μs。测试结果表明电源的输出特性由负载决定,同时调节输入电压、触发脉宽可以改变电源的输出脉冲。研究了针-针放电负载时,电源重复频率以及针针间隙对于放电模式的影响,并通过研究电源输出随负载的变化来区别不同的放电模式,最后把电源成功应用于介质阻挡放电。
等离子体 脉冲功率 高压微秒脉冲 针针放电 介质阻挡放电 plasma pulsed power high voltage microsecond pulse point to point discharge dielectric barrier discharge 
强激光与粒子束
2014, 26(4): 045044
章程 1,2,*顾建伟 1,3邵涛 1,2马浩 1,3[ ... ]杨文晋 1,2
作者单位
摘要
1 中国科学院 电工研究所, 北京 100190
2 中国科学院 电力电子与电气驱动重点实验室, 北京 100190
3 中国科学院大学, 北京 100039
4 电力设备电气绝缘国家重点实验室(西安交通大学), 西安 710049
利用上升沿100 ns、脉宽150 ns的单级磁压缩纳秒脉冲电源,通过电压电流测量和放电图像拍摄实验,研究了大气压空气中极不均匀电场结构重复频率纳秒脉冲气体放电的放电模式。结果表明纳秒脉冲气体放电存在三种典型的放电模式: 电晕放电、弥散放电和火花放电。施加的脉冲电压幅值对放电模式影响显著,随着电压幅值的增加,放电依次经历电晕、弥散和火花放电。固定电压幅值时,放电可能同时存在两种模式。重复频率加强了放电强度,弥散放电的激发电压随重复频率的增加变化不大,但火花放电的激发电压随着重复频率的增加而降低。因此降低重复频率有利于在较大电压范围获得大气压空气弥散放电。
纳秒脉冲 大气压空气 放电模式 弥散放电 重复频率 nanosecond pulse atmospheric-pressure air discharge mode diffuse discharge pulse repetition frequency 
强激光与粒子束
2014, 26(4): 045029

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!